Technical support: 08 9302 4140 Supplied by Radiant Australia Installation manual (PDF)
02

Framed wall installation

Fixing Thermasheet to timber or steel stud walls, internal or external.

Download PDF
Thermasheet Board 10–100 mm Timber & steel studs Internal & external

Overview

Thermasheet can be fixed to timber or steel stud walls in internal or external applications. The boards are lightweight, easy to handle and install, and provide a strong, waterproof and stable substrate for tiles, microcement, render and other finishes.

Key points

  • Bead of MSP Sealant on studs before fixing boards
  • Corrosion-resistant screws with large washers
  • All board edges supported by studs or noggings
  • Seal every joint with MSP Sealant and reinforcing tape

You'll need

  • Thermasheet boards + MSP Sealant
  • Reinforcing tape, screws & washers
  • Utility knife or circular/track saw
  • Driver, caulking gun, level, PPE

Installation steps

  1. 1

    PREPARE FRAME

    Ensure the stud frame is plumb, true and clean, with noggings installed where required. Check services are installed and clear of the board.

    Timber stud wall prior to fixing Thermasheet
    Timber stud wall prior to fixing Thermasheet
  2. 2

    APPLY SEALANT TO FRAME

    Apply a continuous bead of Thermasheet MSP Sealant to the studs at each fixing line before placing the board. This helps with adhesion and support, and minimises movement.

  3. 3

    FIX BOARD

    Position the board against the frame. Fix using corrosion-resistant screws with large washers at the appropriate centres (see the stud spacing guide below). Ensure board-to-board edges are supported by studs or noggings.

    Thermasheet board fixed over frame
    Thermasheet board fixed over frame
  4. 4

    JOIN BOARDS

    Fill all board joints with Thermasheet MSP Sealant and embed Thermasheet reinforcing tape. Ensure a continuous waterproof seal at all joints, corners and penetrations.

    Sealed joints in a Thermasheet-lined shower
    Sealed joints in a Thermasheet-lined shower
  5. 5

    FINISH

    Once the sealant has cured, the surface is ready for tiles, render, microcement or other decorative finishes. Use suitable flexible adhesives and follow the manufacturer's guidelines.

Stud spacing guide: walls

Board thickness Stud centres Notes
6 mm N/A Not recommended for direct fixing to stud walls
10 mm 400–450 mm General wall applications
12 mm 400–450 mm General wall applications
20–100 mm 600 mm General wall applications

Products used in this guide